SHENZHEN LANLING TECHNOLOGY CO., LTDThe Pro manufactuer of stage laser lights and LED lights in China |
|
||||||
News Center
DMX calculation
DMX address calculation
For DMX mode, DMX512 address from #1 to 9# dipswitches must be set, the address is set from 1 to 511. Each dipswitch represents a binary value.
One unit has 5 channels, so each unit must be assigns 5 channels at least. We may assign 8 channels for one unit, then DMX address = 8*N + 1, N=0, 1, 2, 3 …… Example,
One loop address=1, two loop address=9, three loop address=17, four loop address=25
For DMX mode, DMX512 address from #1 to 9# dipswitches must be set, the address is set from 1 to 511. Each dipswitch represents a binary value.
| DIPSWITCH | VALUE | DIPSWITCH | VALUE |
| #1 | 1 | #6 | 32 |
| #2 | 2 | #7 | 64 |
| #3 | 4 | #8 | 128 |
| #4 | 8 | #9 | 256 |
| #5 | 16 | #10 | DMX, Set to “OFF” |
One unit has 5 channels, so each unit must be assigns 5 channels at least. We may assign 8 channels for one unit, then DMX address = 8*N + 1, N=0, 1, 2, 3 …… Example,
One loop address=1, two loop address=9, three loop address=17, four loop address=25
| Loop | Address | Binary | Dipswitches |
| 1 | 1 | 100000000 | #1 |
| 2 | 9 | 100000000 | #1+#4 |
| 3 | 17 | 100000000 | #1+#5 |
| 4 | 25 | 100000000 | #1+#4+#5 |
【 Go Back 】 | 【 Print 】 | 【 Close this window 】